Ultrafiltration (UF) Systems and Membrane Modules
Product Details & Specifications
Ultrafiltration Systems for Turbidity, Colloids and RO Pretreatment
GlobalUF builds ultrafiltration (UF) systems and manufactures its own UF membrane modules for removing turbidity, suspended solids, colloids and microorganisms from surface water, groundwater, seawater intake and treated wastewater. UF is most often used as pretreatment ahead of RO or SWRO, or as a final barrier where low-turbidity water is required. UF does not remove dissolved salts, so it cannot solve a high-TDS problem on its own.

What Does an Ultrafiltration System Remove, and What Does It Not Remove?
A UF membrane is a physical barrier for particles, colloids and microorganisms; it is not a desalination membrane. Dissolved salts, hardness and most dissolved ions pass through UF and must be handled by RO, NF or another process if the target water requires it.
| Water problem | Can UF address it? | Typical next step |
|---|---|---|
| Turbidity and TSS | Yes | Coagulation or filtration ahead of UF when loads are high |
| Colloids and high SDI before RO | Yes | UF → cartridge filter → RO / SWRO |
| Bacteria and other microorganisms | Yes, as a barrier | Disinfection is still selected for the target water |
| High TDS, salinity, hardness | No | BWRO, SWRO or NF |
| Dissolved iron and manganese | Not on its own | Oxidation / pH adjustment and filtration first |

Typical UF Process Routes
The UF route depends on the water source and the treatment step that follows it. These are typical routes; the final route is selected from the water analysis.
| Water source | Typical route |
|---|---|
| Surface water | Coagulation → Filtration → UF |
| High-turbidity groundwater | Coagulation / Sedimentation → Filtration → UF → RO |
| Seawater | Pretreatment → UF → SWRO |
| Industrial high-purity water | UF → RO → RO / EDI / Polishing |
| Wastewater reuse | Biological treatment / MBR → UF (optional) → RO |
For seawater projects, the choice between media filters and UF is explained in Seawater Desalination Pretreatment: When to Choose Media Filters or UF.
Typical Configuration
Typical values – subject to water analysis and project requirements.
| Item | Typical configuration |
|---|---|
| Supply scope | Complete ultrafiltration system (UF skid with pumps, valves, piping, instruments and controls), or GlobalUF UF membrane modules only |
| UF membrane modules | Manufactured by GlobalUF; available under the customer’s own brand (OEM) |
| Flow direction | Outside-in or inside-out hollow-fiber modules, selected for the feed water and cleaning method |
| Membrane material | PVDF or PVC, selected for the feed water, cleaning chemicals and project requirements |
| Customization | Flow direction, membrane material, module arrangement and skid layout can be customized |
| Operating cycle | Filtration, hydraulic backwash, chemically enhanced backwash (CEB) and clean-in-place (CIP) |
| Cleaning triggers | Based on transmembrane pressure (TMP), flow decline and fouling type, not a fixed schedule |
| Upstream protection | Screening, coagulation, sedimentation or media filtration, depending on the feed water |
| Low-pressure piping | UPVC is common; material is confirmed for the water and chemicals used |
| Automation | Siemens PLC with 10″ HMI is a common option; remote monitoring is optional |
| Testing | Factory acceptance testing (FAT) before shipment |

What should you check before changing RO pretreatment to UF?
Start with the problem the existing pretreatment is failing to control. Record the water quality before and after filtration, changes during difficult operating periods, filter pressure trends and RO cleaning history. These records help distinguish a solids-control problem from a problem that needs a different treatment step.
Compare the proposed UF arrangement with the existing pretreatment at the same required net flow to RO. Ask how upstream protection, backwash, cleaning, waste handling and unavailable trains affect usable daily output. Define the outlet acceptance criteria and monitoring method for the selected RO membrane, rather than assuming that a generic UF module rating guarantees the result.
For seawater intake, use the media filtration versus UF pretreatment comparison to assess the complete treatment arrangement.
Do you need replacement modules or a complete UF system?
- Replacement UF membrane modules: send the existing manufacturer and model, quantity, nameplate photograph, dimensions and connection drawing. Include membrane material, flow direction, operating conditions and the chemicals used for cleaning. Matching external dimensions alone does not establish compatibility.
- A complete UF system: provide the feedwater analysis, required net output, operating hours, downstream process and available utilities. Ask the quotation to define the pumps, valves, instruments, controls, cleaning equipment and site interfaces included.
- An upgrade to an existing rack: identify which pumps, pipework and controls will be retained. Confirm that the proposed modules and operating sequences are compatible with those components.
Request the selected module datasheet and its operating and chemical-cleaning limits. State whether quoted flow is gross filtration output or net usable output after backwash and other losses. Use the existing form below and identify the request as modules, a complete system or a retrofit.
Backwash, CEB and CIP
A UF system keeps its flow by combining frequent hydraulic backwash, periodic chemically enhanced backwash (CEB) and occasional full clean-in-place (CIP). The cleaning chemicals and their sequence depend on the fouling type and the membrane manufacturer’s limits, so no single cleaning recipe fits every project. See our engineering notes on UF membrane cleaning: CEB, CIP and chemicals and on planning a membrane CIP system.

Applications
- RO and SWRO pretreatment: lowering suspended solids and colloids before RO membranes, including brackish water RO systems.
- Surface and river water: clarification for drinking water and industrial supply, usually after coagulation and filtration.
- High-turbidity groundwater: UF between clarification and RO.
- Industrial and high-purity water: the first membrane barrier ahead of RO and EDI.
- Wastewater polishing and reuse: removing remaining solids before discharge or RO.
Typical buyers include overseas EPC contractors, RO system integrators, OEM brand owners, industrial end users and water utilities.
UF Project References
- 2000 m³/day UF system for industrial park domestic water (Jiangxi, China): flocculant dosing, quartz sand filtration, UF and bactericide dosing.
- 100 m³/day integrated skid-mounted UF system (Malaysia): coagulation, sedimentation and filtration ahead of out-to-in UF, with automatic backwash and CEB based on TMP.
- 100 m³/day groundwater purification system (Johor, Malaysia): clarification, UF and RO for high-turbidity well water.
- Tianjin Nangang seawater desalination project: GlobalUF was the core OEM supplier of the key UF + SWRO membrane equipment for the EPC contractor.
Each figure above applies only to that project.
Frequently Asked Questions
Can UF remove salt or reduce TDS?
No. UF removes particles, colloids and microorganisms, but dissolved salts pass through. If TDS, salinity or hardness must be reduced, UF is followed by RO, SWRO or NF.
Do I need UF before RO?
Not always. UF is considered when the feed water has high or variable turbidity, colloids or SDI that conventional filtration cannot control reliably. The decision is made from the water analysis and the RO membrane’s feed requirements.
Can you supply UF membrane modules only, or under our own brand?
Yes. GlobalUF manufactures its own UF membrane modules. Besides complete ultrafiltration systems, we supply modules to system integrators, overseas EPC contractors and existing plants, and we produce OEM modules under the customer’s brand. For module-only orders, tell us the existing module type, connection size, operating conditions and cleaning chemicals in use.
Should I choose outside-in or inside-out, PVDF or PVC UF modules?
GlobalUF supplies both outside-in and inside-out modules, in PVDF or PVC. The choice depends on the feed water’s turbidity and solids load, the cleaning chemicals planned, the backwash method and the budget, so it is made from the water analysis rather than fixed in advance.
How often does a UF system need cleaning?
It depends on the feed water. Backwash and CEB intervals, and the point at which CIP is needed, are set from TMP trends, flow decline and the fouling type, following the membrane manufacturer’s guidance.
What information do you need for a UF quotation?
Feed water analysis (turbidity, TSS, SDI, pH, temperature, organics and other applicable values), required capacity in m³/h or m³/day, target water use, operating hours per day, power supply and any preferences for automation, materials or brands. See our quotation checklist.
Request a Project-Specific Ultrafiltration System Proposal
Send us your water analysis, capacity and target water quality, and our engineers will recommend an ultrafiltration system route and configuration, or the UF membrane modules for your existing plant or OEM program. Final design is subject to the complete feed-water analysis and confirmed project requirements.
Request a Quote for This Product
Discuss your water treatment needs with our experts. We'll get back to you within 24 hours.